Add: anynu35 - Date: 2020-11-27 07:55:58 - Views: 9945 - Clicks: 7580

52 in) Ethernet 100 m (328. Electrical Supplies & Automation Distributor | PA, OH, WV | ACD. DataSheet in PDF Download: Service & Support (Manuals, Certificates, FAQs. 6SL3040-1LA00-0AA0 and CU310-2PN, Order No. 1 × Antrieb SINAMICS S120 CU310-2 PN V4.

pptx - Free download as Powerpoint Presentation (. S120 with CU310- cu310-2 pn manual pdf 2 DP/PN S120 with CU320- 2 DP/PN S150 with CU320- 2 DP/PN G130 with CU320- 2 DP/PN G150 with CU320- 2 DP/PN Diagnostic and parameterization functions for all "High-end" SINAMICS drives independent of the commissioning tool Access via all TCP/IP -capable interfaces PN-networked devices can use the. Additional Info: Control Unit CU310-2 PN, With Profinet Interface, Without Compact Flash Card Downloads. 04 ft) PROFINET 2 - - Width DRIVE-CLiQ HTL encoder unipolar signal DC 24 V (20,4.

CU310-2 PN and SIMOTION D4x5-2 Control Units CU310-2 DP and CU310-2 PN Control Units CU310-2 Control Units are designed to control a single drive. 5 mm2 Fuse protection, max. Data Sheet 1 Help Desk. 3 sp1 hf3 product brand name simotion product-type designation d410-2 dp/pn. 6sl3040-1la01-0aa0 sinamics s120 control unit cu310-2 pn sinamics s120 control unit cu310-2 pn with profinet interface without compactflash card. at any time and without prior notice. For all CUs of the SINAMICS S120 family (CU310-2 and CU320-2), the web server is available via the commissioning interface (X127) from firmware version V4. CU310-2 PN • KTP1000 basic color ;.

35 A for CU. txt) cu310-2 pn manual pdf or read book online for free. At 24 V DC, without taking account of digital outputs and DRIVE-CLiQ supply 0. See technical manual for possible combinations. SINAMICS S120 CONTROL UNIT CU310-2 PN WITH PROFINET INTERFACE WITHOUT COMPACTFLASH CARD. Sinamics G120 Cu240e-2 Pn Manual >>>CLICK HERE. Function Manual Firmware version 4. 1 Power Modules PM250 Available Power Modules There are the following types of Power Modules with regenerative braking capacity.

28,8 V) CE, KC, cULus, EAC, C-Tick (RCM. PAGE 1/1 KRØLL CRANES A/S ALARM LIST Mes. 5 (6SL3 040-1LA01-0AA0) 1 × Antrieb SINAMICS G120 CU240E-2 PN(-F) V4. I am using Siemens CPU 317F-2 PN/DP. CU320-2 Control Unit. Hello, I would like to know how to properly reset fault in G120 drive over Profinet VFD has CU240E-2 PN control module.

Siemens 6SL3040-1LA01-0AA0 SIEMENS SINAMICS S120 CONTROL UNIT CU310-2 PN WITH PROFINET INTERFACE part of Motors and Motor Drives, distributed by Kempston Controls. SINAMICS S120 Control Unit CU310-2 PN, w/o CF Card: call for stock: 3RH1921-1DA11: Automation: Siemens 6A Auxiliary Contactor - 3RH Range. 5 A for PM340 Power Module Conductor cross-section, max. This ensures that all your saved data (firmware, licenses, parameters) will be available to you immediately again to commission a replacement unit. Data sheet for SINAMICS S120 control unit CU310-2 PN MLFB-Ordering data Figure similar 30 bit 0. pdf), Text File (. txt) or view presentation slides online. Cause Erection condition selected, overload equipment cut out Phase fault or under voltage alarm from relay U6.

They feature as standard a PROFIBUS interface (CU310-2 DP) or PROFINET interface (CU310-2 PN) and a TTL/HTL cu310-2 pn manual pdf encoder evaluation circuit. Siemens S120_EN_rev. Preface Commissioning Manual Commissioning Manual, (IH1), 01/, 6SL3097-4AF00-0BP1 5 Standard scope The scope of the functionality described in this document may differ from the scope of the. Preface Getting Started Getting Started, 01/, 6SL3097-4AG00-0BP2 5 Benefits This Manual describes all the information, procedures and operational instructions required. Valid for: SINAMICS S120 with CU320-2 or CU310-2 Hardware prerequisites: The firmware versions that can be used depend on the hardware release of the Control Units. Siemens Industry Catalog - Drive technology - Converters - Low-voltage converters - Servo drives - SINAMICS S110 servo drives - CU305 Control Unit. 1 · 2 Overview The CU310 PN Control Unit is designed for the communication and open-loop/closed-loop control functions of a Power Module.

20 A Digital inputs in accordance with IECType 1. The CU310-2 is used in conjunction with power modules and single-motor drives whereas the CU320-2 is used with all motor modules or line modules for both single and multi-motor drives. Sinamics Manual | Electromagnetic Compatibility | Trademark. Funciones del Sistema Sinamics S120. The Connection Parameters section configures the IO Assemblies for the CU320-2. 1 Power Modules PM250 Power Module PM250 8 Hardware Installation Manual, 07/, A5E01003502B AC 1.

If there are any differences between the. 6sl3040-1la01-0aa0 sinamics s120 control unit cu310-2 pn sinamics s120 control unit cu310-2 pn with profinet interface without compactflash card. 5 (6SL3 244-0BB1x-1FA0) Software-Voraussetzungen Um das Getting Started durchzuführen, benötigen Sie folgende Software -Komponenten: SIMATIC STEP 7 Professional V12. 5 drive (6SL3 244-0BB1x-1FA0) Software requirements You need the following software components to run the Getting Started: SIMATIC STEP 7 Professional V12 SIMATIC WinCC Advanced V12 or SIMATIC WinCC Professional V12. The CU310-2DP, Order No. 35 A SSI baudrate PROFIBUS 24 V SSI absolute position resolution at 40 °C (104 °F) 191 mm (7. Shipping to 240+ countries worldwide.

docx 2-1 2 SAFETY INSTRUCTIONS AND PRECAUTIONS Read all of this manual before powering the equipment, following step by step the procedures. CU310-2 Control Unit PROFINET: 6SL3040-1LA01-0AA0 PROFIBUS:6SL3040-1LA00-0AA0 Current requirement, max. 2)SSM possible only for CU240E-2 DP-F / CU240E-2 PN-F Control Units with PROFIsafe.

pptx), PDF File (. SINAMICS S120 modular drives are designed for motion control and high-performance drive applications in mechanical and systems engineering, with both single drives and coordinated drives (multiple-axis applications) with vector or servo functionalities that allow implementation of customized high performance drive solutions for the ultimate in flexibility and increased productivity. Phone:. com com.

The Assembly Instances should always be 101 through 103 for the Input, Output and Configuration Assembly respectively. SINAMICS Family of Drives PM VS CU Compatibility. For CUs with PROFINET interface, the web server can also be accessed via this interface (onboard PROFINET). 3)With license for Extended Safety functions. SIEMENS 6SL3040-1LA00-0AA0 - Sinamics S120 control unit CU310-2 DP with profibus interface. 1 × SINAMICS S120 CU310-2 PN V4. 6SL3040-1LA01-0AA0 are supported from FW4.

dp/pn; programmable single-axis motion controller with multi-axis option; interfaces: 5 di, 8 di/do, 3 f-di, 1 f-do, 1 ai, 1 encoder, 1 drive-cliq, 1 profibus, 2 profinet ports, 1 ethernet note: requires at least scout/firmware v4. The web server provides information on a SINAMICS device via its web pages. SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/ Product: SINAMICS G120, Version: 4402100, Language: eng, Objects: CU230P-2 CAN, CU230P-2 DP, CU230P-2 HVAC. What&39;s New in SINAMICS Drives and SIMOTICS Motors Presented by Mark Martina Manufacturing in America │ March 20-21, Unrestricted © Siemens. CU240E-2 PN supported. The CU310 PN combined with a Power Module and CompactFlash card creates a powerful single axis AC drive.

4 03/ A5E03264275A Preface Typicals and regulations 1 General information about SINAMICS Safety Integrated 2 System Features 3 Supported functions 4 Safety Integrated Basic Functions 5 Safety Integrated Extended Functions 6 Controlling the safety functions 7 Commissioning 8 Application examples 9. call for stock: 6XV1830-0EH10: SINAMICS: GM/SM150 Converter Accessory: call for stock: 6XV1840-2AH10: SINAMICS: Standard Cable GP 2x2: call for stock: 6AV2123-2GA03-0AX0: SIMATIC: SIMATIC HMI, KTP700 BASIC. The communication link to the higher-level control is. Different versions of these control units include: CU305 DP – 6SL3040-0JA00-0AA0; CU305 PN – 6SL3040-0JA01-0AA0; CU310-2 DP – 6SL3040-1LA00-0AA0. pdf This document. s Sinamics S120: Lab 04 SINAMICS MDI & Traversing Block Positioning with S7-315 PLC Febu Page 2 of 32 Siemens Energy & Automation, Inc.

6 Configuring a Generic Ethernet Module Enter the IP Address of the CU320-2 PN or CU310-2 PN. CU310-2 PN Inserting the memory card The memory card in a faulty CU310-2 PN If you are returning a faulty CU310-2 PN to Siemens, remove the memory card and keep it in a safe place. DDS (Distributor Data Solutions). Sinamics S120 Manua de Funcionesl - Free ebook download as PDF File (. CU310 PN Control Unit 2/20 Siemens D 21.